Publicación:
Evaluación de los niveles de iluminación en los puestos de trabajo administrativos de Distrisec Solutions S.A.S. de la ciudad de Montería

dc.contributor.advisorEscudero Pérez, Jorge Luisspa
dc.contributor.authorFlórez Salgado, Juan José
dc.date.accessioned2023-02-25T14:13:53Z
dc.date.available2023-02-25T14:13:53Z
dc.date.issued2023-02-23
dc.description.abstractFrom the point of view of occupational health and safety, inadequate lighting conditions in the workplace can have negative impacts on the health of employees, ranging from blurred vision, tearing and headaches, and in the worst case, it can be the trigger for work accidents. In this project, the lighting conditions of the administrative jobs of Distrisec Solutions S.A.S were evaluated, through hygienic measurements and a qualitative perception survey. The results obtained in the hygienic measurements, it’s possible to affirm that, of the administrative jobs evaluated, only one meets the minimum requirements established in the current regulations. In relation to symptoms manifested during and after the workday, the surveyed collaborators refer a feeling of eye fatigue, headache and heaviness in the eyelids. Finally, measures based on the principles of risk control were proposed, in order to guarantee the visual health of employees and improve the management of risks associated with inadequate lighting conditions.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en Higiene y Seguridad Industrialspa
dc.description.modalityTrabajos de Investigación y/o Extensiónspa
dc.description.resumenDesde el punto de vista de la seguridad y salud en el trabajo, las condiciones de iluminación inadecuadas en los puestos de trabajo pueden generar impactos negativos en la salud de los colaboradores, que van desde visión borrosa, lagrimeo y dolor de cabeza, y en el peor de los casos, puede ser el detonante de accidentes de trabajo. En el presente proyecto se evaluaron las condiciones de iluminación de los puestos de trabajo administrativos de Distrisec Solutions S.A.S, a través de la realización de mediciones higiénicas y una encuesta de percepción cualitativa. Los resultados obtenidos en las mediciones higiénicas es posible afirmar que, de los puestos de trabajo administrativos evaluados solo uno cumple con los requisitos mínimos establecidos en la normatividad vigente. En relación con síntomas manifestados durante y después de la jornada laboral, los colaboradores encuestados refieren sensación de fatiga ocular, dolor de cabeza y pesadez en los párpados. Finalmente, se propusieron medidas basadas en los principios del control del riesgo, a fin de garantizar la salud visual de los colaboradores y mejorar la gestión de los riesgos asociados a condiciones inadecuadas de iluminación.eng
dc.description.tableofcontentsIntroducción ……………………………………………………………………………… 3spa
dc.description.tableofcontents1 Presentación de la Empresa ......................................................................................................... 5spa
dc.description.tableofcontents1.1 Plataforma Estratégica ............................................................................. 5spa
dc.description.tableofcontents1.1.1 Misión ...................................................................................... 5spa
dc.description.tableofcontents1.1.2 Visión ........................................................................................................................ 6spa
dc.description.tableofcontents1.1.3 Valores Corporativos............................................................................................. 6spa
dc.description.tableofcontents1.1.4 Política de Seguridad y Salud en el Trabajo.............................................................. 7spa
dc.description.tableofcontents1.2 Organigrama.............................................................................. 8spa
dc.description.tableofcontents1.3 Mapa de Procesos............................................................... 9spa
dc.description.tableofcontents1.4 Jornada Laboral............................................................................. 10spa
dc.description.tableofcontents1.5 Área de Trabajo y Descripción de la Tarea................................................................ 10spa
dc.description.tableofcontents2 Descripción y Formulación del Problema............................................. 17spa
dc.description.tableofcontents2.1 Formulación del Problema............................................................................. 18spa
dc.description.tableofcontents3 Marco Referencial................................................................................................... 19spa
dc.description.tableofcontents3.1 Marco Teórico................................................................................................................. 19spa
dc.description.tableofcontents3.1.1 Seguridad y Salud en el Trabajo e Higiene Industrial..................... 19spa
dc.description.tableofcontents3.1.2 Peligro Físico.................................................................................................................. 20spa
dc.description.tableofcontents3.1.3 Sistemas de Iluminación.................................................................................... 21spa
dc.description.tableofcontents3.1.4 Aspectos Para Tener en Cuenta en los Puestos de Trabajo Administrativos ...................... 24spa
dc.description.tableofcontents3.1.5 Efectos en la Salud Asociados a Condiciones Inadecuadas de Iluminación en el Trabajo ............................... 26spa
dc.description.tableofcontents3.1.6 Medidas de Control Riesgo de Iluminación Inadecuada ................. 29spa
dc.description.tableofcontents3.2 Marco Conceptual..................................................................................................... 31spa
dc.description.tableofcontents3.3 Marco legal.........................................................................................................................36spa
dc.description.tableofcontents4 Justificación .............................................................................................................. 38spa
dc.description.tableofcontents5 Objetivos............................................................................................................................ 40spa
dc.description.tableofcontents5.1 Objetivo General..................................................................................................... 40spa
dc.description.tableofcontents5.2 Objetivos Específicos ............................................................................................... 40spa
dc.description.tableofcontents6 Metodología y Trabajo de Campo.......................................................................... 41spa
dc.description.tableofcontents6.1 Alcance y Tipo de Estudio ....................................................................................... 41spa
dc.description.tableofcontents6.2 Población y Sitio de Medición.............................................................................. 41spa
dc.description.tableofcontents6.3 Método......................................................................................................................... 42spa
dc.description.tableofcontents6.3.1 Medición de la Luminancia o Brillo en el Puesto de Trabajo............................ 43spa
dc.description.tableofcontents6.3.2 Niveles de Iluminación y Distribución de las Luminancias........................... 43spa
dc.description.tableofcontents6.4 Instrumento de Recolección de Datos.......................................................... 43spa
dc.description.tableofcontents6.5 Instrumento de Medición................................................................................. 44spa
dc.description.tableofcontents6.6 Medición en Campo............................................................................................ 46spa
dc.description.tableofcontents7 Resultados .........................................................................................................................48spa
dc.description.tableofcontents7.1 Diagnóstico Cualitativo ......................................................................................... 48spa
dc.description.tableofcontents7.2 Encuesta a los Trabajadores............................................................................... 50spa
dc.description.tableofcontents7.3 Medición Higiénica (Luxometría) ......................................................................57spa
dc.description.tableofcontents7.4 Recomendaciones .............................................................................................. 59spa
dc.description.tableofcontents7.5 Socialización de los Resultados con Partes Interesadas ................. 60spa
dc.description.tableofcontents8 Conclusiones ........................................................................................................... 61spa
dc.description.tableofcontents6. Bibliografía .............................................................................................................. 63spa
dc.description.tableofcontentsANEXOS .................................................................................................................................... 68spa
dc.format.mimetypeapplication/pdfspa
dc.identifier.urihttps://repositorio.unicordoba.edu.co/handle/ucordoba/7215
dc.language.isospaspa
dc.publisher.facultyFacultad de Ingenieríaspa
dc.publisher.placeMontería, Córdoba, Colombiaspa
dc.publisher.programIngeniería Industrialspa
dc.rightsCopyright Universidad de Córdoba, 2023spa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)spa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.subject.keywordsLightingeng
dc.subject.keywordsPhysical riskeng
dc.subject.keywordsVisual healtheng
dc.subject.keywordsRetilapeng
dc.subject.proposalIluminaciónspa
dc.subject.proposalRiesgo físicospa
dc.subject.proposalSalud visualspa
dc.subject.proposalRetilapspa
dc.titleEvaluación de los niveles de iluminación en los puestos de trabajo administrativos de Distrisec Solutions S.A.S. de la ciudad de Monteríaspa
dc.typeTrabajo de grado - Especializaciónspa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa
dc.type.versioninfo:eu-repo/semantics/submittedVersionspa
dcterms.referencesACIMED. (Abril de 2007). Síndrome de la visión del ordenador: cuando la herramienta se convierte en enemiga. 15(4). Recuperado el 13 de 09 de 2022, de http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1024-94352007000400024&lng=es&tlng=es.spa
dcterms.referencesArrieta S, M., Guzmán E, R., & Sánchez S, A. (2021). Evaluación de condiciones de iluminación en puestos de trabajo de los guardas de seguridad. Tolima. Recuperado el 18 de 09 de 2022, de https://repository.uniminuto.edu/bitstream/10656/12452/1/UVDT.SO_S%C3%A1nchezAna-ArrietaManuel-GuzmanRobinson_2021.pdfspa
dcterms.referencesBeltrán M, J. J., & Merchán A, C. E. (2013). NIVELES DE ILUMINACIÓN Y SU RELACIÓN CON LOS POSIBLES EFECTOS VISUALES EN LOS EMPLEADOS DE UNA IPS DE BOGOTÁ. Fisioterapia iberoamericana, 7. doi:10.33881spa
dcterms.referencesGarrido L, A. C., & Trujillo B, Y. A. (2015). ESTUDIO DE ILUMINACIÓN DE LOS PUESTOS DE TRABAJO ADMINISTRATIVOS DE LA EMPRESA COMERCIALIZADORA INTERNACIONAL VERDE AZUL S.A.S. Bogotá, Cundinamarca, Colombia. Obtenido de https://repository.udistrital.edu.co/bitstream/handle/11349/2907/GarridoLopezAndreaCatalina2016.pdf?sequence=1&isAllowed=yspa
dcterms.referencesGonzalez P, J., Gonzales J, J., & Garcia M, R. (2013). UF0567: Eficiencia energética en las instalaciones de iluminación interior y alumbrado exterior. España: IC Editorial.spa
dcterms.referencesGrass M, Y., Castañeda D, M., Pérez S, G., Berenguer G, M., & R, C. (2017). La iluminación como agente físico negativo en un servicio estomatológico. MEDISAN Revista médica de santiago de cuba, 7. Obtenido de http://scielo.sld.cu/pdf/san/v21n3/san03203.pdfspa
dcterms.referencesHenao R, F. (2011). RIESGOS FÍSICOS II ILUMINACIÓN (Segunda ed.). Bogota D.C., Colombia: ECOE ediciones. Recuperado el 04 de 09 de 2022, de http://fullseguridad.net/wp-content/uploads/2017/10/Riesgos-f%C3%ADsicos-II-Fernando-Henao-Robledo.pdfspa
dcterms.referencesHernández S, R., Fernández C, C., & Baptista L, M. (2014). Metodología de la investigación (Sexta ed.). Punta Santa fe, Mexico: Mc Graw hill education. Recuperado el 04 de 09 de 2022, de https://periodicooficial.jalisco.gob.mx/sites/periodicooficial.jalisco.gob.mx/files/metodologia_de_la_investigacion_-_roberto_hernandez_sampieri.pdfspa
dcterms.referencesHerrick, R. (1998). Capítulo 30: Higiene Indutrial. En Enciclopedia de salud y seguridad en el trabajo (4 ed., Vol. 1). Chantal Dufresne, BA. Retrieved 17 de 09 de 2022, from https://www.insst.es/documents/94886/161958/Cap%C3%ADtulo+30.+Higiene+industrial#:~:text=La%20higiene%20industrial%20es%20la,su%20posible%20repercusi%C3%B3n%20en%20lasspa
dcterms.referencesHernández, H. (2015). Estudio de iluminación para prevenir enfermedades ocupacionales. TOG (A coruña), 12(22), 13. Recuperado el 13 de 09 de 2022, de https://dialnet.unirioja.es/servlet/articulo?codigo=5308781spa
dcterms.referencesInstituto Nacional de Seguridad e Higiene en el Trabajo (INSHT). (2015). ILUMINACIÓN EN EL PUESTO DE TRABAJO. Madrid, España: Instituto Nacional de Seguridad e Higiene en el Trabajo (INSHT). Recuperado el 04 de 09 de 2022, de https://www.insst.es/documents/94886/96076/Iluminacion+en+el+puesto+de+trabajo/9f9299b8-ec3c-449e-81af-2f178848fd0aspa
dcterms.referencesInstituto Nacional de Seguridad y Salud en el Trabajo - INSST. (s.f). Instituto Nacional de Seguridad y Salud en el Trabajo. Retrieved 19 de 09 de 2022, from https://www.insst.es/-/medidas-preventivas-gen-ilspa
dcterms.referencesInstituto Sindical de Trabajo, Ambiente y Salud [ISTAS]. (2007). La prevención de riesgos en los lugares de trabajo (Quinta edición ed.). https://doi.org/ISBN 84-607-3133-2spa
dcterms.referencesMinisterio de Minas y Energía. (2010). Resolución 180540. Colombia. Retrieved 4 de 10 de 2022, from https://www.sic.gov.co/sites/default/files/files/2021/Resoluci%C3%B3n%20180540%20de%202010.pdfspa
dcterms.referencesMinisterio de Salud. (1979). Ley 9. Colombia. Retrieved 4 de 10 de 2022, from https://www.minsalud.gov.co/Normatividad_Nuevo/LEY%200009%20DE%201979.pdfspa
dcterms.referencesMinisterio de trabajo y seguridad social. (1979). Resolución 2400. Colombia. Retrieved 28 de 01 de 2023, from https://www.ilo.org/dyn/travail/docs/1509/industrial%20safety%20statute.pdf Ministerio del Trabajo. (26 de Mayo de 2015). Decreto 1072. Retrieved 04 de 10 de 2022, fromspa
dcterms.referencesMondelo, P., Gregori T, E., González, O., & Gómez F, M. (30 de junio de 2013). Mutua universal (Segunda ed.). Edicions UPC. Retrieved 10 de 10 de 2022, from Mutua universal: https://upcommons.upc.edu/bitstream/handle/2099.3/36777/9788476539828.pdspa
dcterms.referencesMunive A, J. (junio de 2020). Calidad de la iluminación en las aulas de clase en una Institución de Educación Superior. Investigación e innovación en ingenierías, 8(1), 192-201. doi:10.17081spa
dcterms.referencesOchoa E, A., & Hernández C, Y. (2021). Relación entre la Iluminación, la virtualidad y los efectos en la salud visual en trabajadores y estudiantes: una revisión de la literatura entre los años 2010 al 2021. Trabajo de grado, Universidad de antioquia, Medellín. Recuperado el 13 de 09 de 2022, de https://bibliotecadigital.udea.edu.co/bitstream/10495/23842/3/OchoaAlexandra_HernandezYohan_2021_IluminacionVirtualidadEfectos.pdfspa
dcterms.referencesOrganización Internacional del Trabajo [OIT]. (2018). Mejorar la Seguridad y la Salud de los Trabajadores Jóvenes. Suiza: OIT. https://doi.org/ISBN 978-92-2-131651-0spa
dcterms.referencesPOSITIVA COMPAÑÍA DE SEGUROS S.A. (2017). INFORME DE EVALUACIONES OCUPACIONALES NIVELES DE ILUMINACION. Bogota. Recuperado el 18 de 09 de 2022, de http://sgi.ideam.gov.co/documents/412030/55492482/Informe+Iluminaci%C3%B3n+aerop+C%C3%BAcuta+2017.pdf/2868e80e-5d3a-4dcd-af5c-f3c07e2bc188?version=1.0spa
dcterms.referencesRacines G, C., & Lozada A, M. (2019). Niveles de iluminación en puestos de trabajo de una EPS del régimen contributivo de Santiago de Cali para el año 2019. Santiago de chile. Retrieved 04 de 09 de 2022.spa
dcterms.referencesSecretaría de Ciencia y Tecnología de la Universidad Tecnológica Nacional - U.T.N. (2006). Manual de Iluminación Eficiente. Buenos aires, Argentina: Universitaria de la U.T.N. doi:978-950-42-0077-2spa
dcterms.referencesYánez Yánez, O. (2022). Los Niveles De Iluminación En Áreas Laborales De Una Planta De Acero: A Propósito De Un Caso. Quito. Recuperado el 04 de 09 de 2022, de https://repositorio.uisek.edu.ec/bitstream/123456789/4532/1/Y%c3%a1nez%20Y%c3%a1nez%20Oswaldo%20Paul.pdfspa
dspace.entity.typePublication
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2spa
oaire.versionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
Archivos
Bloque original
Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Florezsalgadojuanjose.pdf
Tamaño:
2.11 MB
Formato:
Adobe Portable Document Format
Descripción:
No hay miniatura disponible
Nombre:
AutorizaciónPublicación..pdf
Tamaño:
325.92 KB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
14.48 KB
Formato:
Item-specific license agreed upon to submission
Descripción: